top of page

Arc Flash and Electrical Safety Best Practices (NFPA 70E 2024)

Arcflash

blank.png

Learning objectives


  • Differentiate between arc flash and electric shock

  • Recall hazards, injuries, and indirect consequences related to arc flash and electric shock

  • Recognize the way approach protection boundaries are determined

  • Match approach boundary criteria with worker qualifications

  • Identify necessary training and skills for qualified workers

  • Recall primary elements of an electrical safety program

  • Recognize the purpose of lock and tag procedures

  • Identify different types of lock and tag devices

  • Identify basic procedural steps for lock and tag

  • Identify the requirements for the use of test instruments and equipment

  • Recall the requirements, benefits, and components of a job briefing

  • Identify the requirements, benefits, and components of an energized work permit

  • Recall PPE responsibilities and requirements related to work around energized electrical equipment and parts


Course overview


What is NFPA 70E (Arc Flash)?


We offer National Fire Protection Association training for electrical safety in the workplace.


For linemen and other utility workers, death by electrocution is a daily hazard that requires attention. In the utility sector, awareness of electrical hazards must be a daily theme for safety and training professionals.


To reduce the risk of injury in the utility industry, trade associations and federal agencies now have many safe work practices and procedures in place to protect employees when working on or near energized electrical equipment and conductors. Current regulations and industry standards are now in place to protect electrical workers from the hazards of shock, electrocution, arc flash, and arc blast.


The two main regulatory bodies that govern electrical safety in the workplace are the National Fire Protection Association (NFPA) and the Occupational Safety and Health Administration (OSHA). The National Fire Protection Association is recognized for providing information and guidelines that protect workers from electrical hazards, while OSHA is the enforcement agency for electrical safety in the workplace.


Industry Standards Governing Electrical Hazards


  • NFPA Standards

  • 70-NEC

  • 70B Maintenance Electrical

  • 70E “Standard for Electrical Safety in the Workplace”


To ensure employees have a safe workplace, your company is required to provide electrical safety training to employees who face a risk of electrical hazards that is not reduced to a safe level by the applicable electrical installation requirements.


NFPA 70E (Arc Flash Training) Must Include:


  1. Specific hazards associated with electrical energy.

  2. Safe work practices and procedures necessary to provide protection from electrical hazards associated with jobs or tasks.

  3. Identification of the relationship between electrical hazards and possible injury.


If there is a big, recent change in the way your workforce operates or interacts with electrical equipment or power generation devices, safety professionals have to make changes to protect the workforce, accordingly.


If supervision or annual inspections indicate that employees are not complying with the safety-related work practices, retaining, or refresher training, is then required. Retraining is also required if new technology, equipment types, or changes in processes alter the safe work practices, or if workers must employ safe work practices that are not normally used during regular job duties.


Additionally, for tasks performed less than once a year, retraining is required before employees go back in the field for the performance of related work.


For example, NFPA 70E 110.2 (E) states employers must document that each employee has received the training required for qualified and unqualified employees.


Training Documentation Requirements


  1. Include employee names and dates of training.

  2. Be made when the employee demonstrates proficiency in the work practice involved.

  3. Be maintained for the duration of the employee’s employment.


Electrical tasks that involve working on or near energized electrical equipment or conductors must be performed only by qualified employees, meaning, employees that have received the necessary training required to safely negotiate specific hazards.


A qualified person is defined as one who has the skills and knowledge related to the construction and operation of the electrical equipment and installations and has received safety training to recognize and avoid the electrical hazards that might be present with respect to that equipment or work method. This person has received additional training and demonstrates proficiency in working on exposed energized equipment, recognizing the hazards associated with the task or job, and taking precautions needed to prevent injury or death.


A qualified person will also be trained in the proper use of special precautionary techniques and in selecting and using the appropriate personal protective equipment (PPE)—including arc flash, insulating and shielding materials, and insulated tool and test equipment. Finally, a qualified person must have proper training in responding to emergency situations. That last one is very important but often overlooked.


To be trained as a qualified employee, the employee must actually do the work or have ‘hands on’, performance-based training. Only trained and qualified employees should ever have access to the space within reach of ‘live’ parts or equipment. NFPA 70E (Arc Flash) requires that only trained and qualified employees can work on or near exposed energized electrical parts and supervise unqualified persons in the vicinity of the hazard.


Another requirement of NFPA 70E (Arc Flash) is the implementation of an overall electrical safety program.


NFPA 70E (Arc Flash) Electrical Safety Program Requirements


  1. Provide awareness training of electrical hazards that includes shock and arc flash.

  2. Include administrative and engineering controls that measure and monitor methods and procedures for working within the Limited Approach Boundary of energized electrical conductors and circuit parts 50 volts or more.

  3. Include a hazard and risk evaluation, and job briefing before each job, for repetitive or similar tasks, and for routine work.

  4. Direct activity appropriate for the voltage, energy level, and circuit conditions.


An Electrical Safety Program must be audited to ensure principles and procedures are being followed. It is important to make sure that your electrical safety program is frequently reviewed, but also measured for performance. The frequency of audits is determined by the employer and based on the complexity of the procedures and the type of work being covered. However, OSHA does require employers to audit their Safety Programs, which include Electrical Safety Programs, at least annually.


NFPA 70E (Arc Flash) 2021 Updates:


The National Fire Protection Association (NFPA) has released the 2021 edition of NFPA 70E, its standard for electrical safety in the workplace. Many states are already adopting compliance with this latest edition to reduce electrical risks in the workplace.


  • New electrical safety program policy

  • Increased focus on capacitor safety

  • Requirements for arc-rated outerwear


Commonly Asked Arc Flash Questions


Question: “I just bought an ARC Flash kit that the rubber gloves had a date of 10/2015. Are these in violation or is the date that they first did the 6 month clock start?”


Answer: You have to test before use. Glove Testing: 1910.335(a)(1)(ii) – Gloves must be tested before first issue and every six months after that. * If the protective equipment has been electrically tested, but not issued for use it may not be placed in service unless it has been electrically tested within the previous 12 months.

Language Offered In.png

English, Spanish, French Canadian

Mobile Ready

Course Time.png

50 min

Course Outline

Course Outline

  • Introduction

  • Arc Flash and Electric Shock

  • Making Work Safe

  • Elements of an Electrical Safety Program

  • The Importance of Best Practices

  • Lock and Tag

  • Use of Test Equipment

  • Job Briefings and Energized Work Permits

  • Personal Protective Equipment

Regulations

Regulations

  • NFPA 70E - Standard for Electrical Safety in the Workplace (2024 Edition)

  • OSHA 1910.335 - Safeguards for Personnel Protection

  • OSHA 1910 Subpart S Electrical

  • OSHA 1910 Subpart I Personal Protective Equipment

  • OSHA 1926.28 Personal Protective Equipment

CURRENT LIBRARY

Click to view other courses in this Library:

Load More >

OTHER LIBRARIES

LIBRARY GROUPS

Overview
Overview
Demo
Pricing
Pricing
Reviews
Reviews
Provider Info
Provider Info

Purchase the Specialty Courses individually.

You can purchase this course in the following ways:

Need Help?

Contact us

800.770.7767

info@SafetyU.com

Library Group Level

Click here to add your own content, or connect to data from your collections.

Priced from:

$550/mo.

Monthly or Annual

See Options
See Plans

Features

Additional Features

See Plans

load more

Course Reviews

+ Add Review
Reviews
average rating is 3 out of 5, based on 150 votes, Product ratings
98% would recommend

This Solution is provided by: 
ESSG
Market Partner.png
ESSG App/Gig Partner
ESSG App/Gig Partner
Support info
Support Email.png
Website.png
Provider Website
SafetyU-logo-train-online-900-black.png
1.800.770.7767
bottom of page